ATEX tubular heater FAW / FAW-C series for zone 1 and 2
These finned tubular heaters are designed to heat, among other things, analysis chambers, small work, storage areas and similar applications, warehouses, ... located in zone 1 or 2 hazardous areas where the flammable atmosphere is a group IIA, IIB or IIC gas.
The standard version comes with a protective cage and is suited for floor mounting. Special brackets for wall mounting are available on request.
General technical specifications
| Earthing | in- and external earthing bolt | ||
|---|---|---|---|
| Protection | IP66 | ||
| Protective grid | standard | ||
| Elements | individually replaceable | ||
| Cable entry | 1x M20 x 1,5 | ||
| Mounting | floor mounting by means of supplied mounting feet | ||
| Ambiant temperature | -60°C - +40°C | ||
| Guideline | ATEX | ||
| Manufacturer | ExHeat | ||
| Suited for |
|
Classification
- II 2 G Ex eb II T3/T4 Gb
Zone
| 0 | 1 | 2 |
| 20 | 21 | 22 |
Ordering data (click on the order reference for more details)
| Order refer. | Range | Voltage | Power | Temperature class |
|---|---|---|---|---|
| FAWC0250-T3-240 | Compact | 240V | 250W | T3 |
| FAWC0500-T3-240 | Compact | 240V | 500W | T3 |
| FAWC0750-T3-240 | Compact | 240V | 750W | T3 |
| FAWC1000-T3-240 | Compact | 240V | 1000W | T3 |
| FAW0250-T3-240 | Standard | 240V | 250W | T3 |
| FAW0500-T3-240 | Standard | 240V | 500W | T3 |
| FAW0750-T3-240 | Standard | 240V | 750W | T3 |
| FAW1000-T3-240 | Standard | 240V | 1000W | T3 |
| FAW1500-T3-240 | Standard | 240V | 1500W | T3 |
| FAW2000SB-T3-240 | Standard | 240V | 2000W | T3 |
| FAW2500-T3-240 | Standard | 240V | 2500W | T3 |
| FAW3000-T3-240 | Standard | 240V | 3000W | T3 |
| FAW0250-T4-240 | Standard | 240V | 250W | T4 |
| FAW0500-T4-240 | Standard | 240V | 500W | T4 |
| FAW0750-T4-240 | Standard | 240V | 750W | T4 |
| FAW1000-T4-240 | Standard | 240V | 1000W | T4 |
| FAW1250-T4-240 | Standard | 240V | 1250W | T4 |
| FAW1500-T4-240 | Standard | 240V | 1500W | T4 |